نتایج جستجو برای: fatigue strength and failure

تعداد نتایج: 16920160  

Journal: :علوم و تکنولوژی پلیمر 0
محمودمهرداد شکریه فتح اله طاهری بهروز

because of inhomogeneity and anisotropy of composite materials, defining a unique fatigue criterion to be suitable for different loading conditions is much more difficult in comparison with traditional materials. for this reason many tests on evaluating the damages such as crack density, stiffness reduction and residual strength are used by various researchers to monitor the fatigue process. in...

Journal: :journal of computational and applied research in mechanial engineering - jcarme 0
j. amirian department of mechanical engineering, isfahan university of technology, 84156-83111, iran h. safari subsea research and development center, isfahan university of technology, 84156-83111, iran m. shirani subsea research and development center, isfahan university of technology, 84156-83111, iran m. moradi department of mechanical engineering, isfahan university of technology, 84156-83111, iran s. shabani subsea research and development center, isfahan university of technology, 84156-83111, iran

generally, fatigue failure in an element happens at the notch on a surface where the stress level rises because of the stress concentration effect. the present paper investigates the effect of a notch on the fatigue life of the hsla100 (­high strength low alloy) steel which is widely applicable in the marine industry. tensile test was conducted on specimens and mechanical properties were obtain...

Journal: :international journal of civil engineering 0
z.y. wang department of civil engineering & mechanics, college of architecture and environment, sichuan university, chengdu, pr china,610065 q.y. wang department of civil engineering & mechanics, college of architecture and environment, sichuan university, chengdu, pr china,610065

this paper presents a finite element analysis and its related experimental test of corrugated steel web beams subjected to fatigue loading. a particular focus in this study was set on the fatigue failure arising from the web-to-flange welded joint of the corrugated steel web beam. a detailed three-dimensional finite element model which explicitly includes the geometry of the web-to-flange welds...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهید چمران اهواز - دانشکده ادبیات و علوم انسانی 1390

this study intends to investigate samuel beckett’s waiting for godot and endgame under the lacanian psychoanalysis. it begins by explaining the most important concepts of lacanian psychoanalysis. the beckettian characters are studied regarding their state of unconscious, and not the state of consciousness as is common in most beckett studies. according to lacan, language plays the sole role in ...

Journal: :journal of dental school, shahid beheshti university of medical sciences 0
رویا امینیان roya aminian dental research center & dental school, shahid beheshti university of medical sciences, tehran, iran.مرکز تحقیقات علوم دندانپزشکی و دانشکده دندانپزشکی، دانشگاه علوم پزشکی شهید بهشتی حسن تراب زاده hassan torabzadeh dental research center & dental school, shahid beheshti university of medical sciences, tehran, iran.مرکز تحقیقات علوم دندانپزشکی و دانشکده دندانپزشکی، دانشگاه علوم پزشکی شهید بهشتی عاطفه صفاری atefe saffari dental school, babol university of medical sciences, babol, iran.([email protected])دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل نسترن مختاری nasrin mokhtari dental school, islamic azad university, tehran, iran.دانشکده دندانپزشکی، دانشگاه آزاد اسلامی تهران علیرضا اکبرزاده باغبان alireza akbarzadeh bagheban shahid beheshti university of medical sciences, tehran, iran.دانشکده پیراپزشکی، دانشگاه علوم پزشکی شهید بهشتی

background and aim: the present study aimed at determination of the fatigue resistance and failure mode of cusp-replacing onlays in endodontically treated premolars using indirect composite resin restorations. materials and method: in this experimental study, 84 human premolars were randomly divided into 7 groups of 12. these groups were prepared as follows: intact teeth used in group1 as contr...

H. Safari J. Amirian M. Moradi M. Shirani, S. Shabani

Generally, fatigue failure in an element happens at the notch on a surface where the stress level rises because of the stress concentration effect. The present paper investigates the effect of a notch on the fatigue life of the HSLA100 (­high strength low alloy) steel which is widely applicable in the marine industry. Tensile test was conducted on specimens and mechanical properties were obtain...

Journal: :علوم و تکنولوژی پلیمر 0
میرحمیدرضا قریشی سعید تقوایی رامین ظفرمهرابیان

this research work is devoted to the investigation on the use of silica on the fatigue-to-failure property of a tire tread compound. a reference compound was frst designed in which 60 phr carbon black was used as the reinforcing fller. while keeping the total of fller content to be constant as 60 phr, three additional compounds with 5, 10 and 20 phr silica were then manufactured. the classical ...

H. Sharifi, M. Salehi, M.R. Saeri

The effect of ferrite grain size on the fatigue and tensile properties of dual phase steels with a 0.25 volume fraction of martensite (Vm) under different heat treatments was investigated. The heat treatments were homogenized at 1200 oC along with several subsequent normalizations at 910 oC, resulting in different microstructures and mechanical properties. After heat treatment, the obtained ste...

Excellent mechanical properties and fatigue performance of Al/Al2O3 metal-based nanocomposites caused to introduce this material as a good candidate for various applications. In this regard, the preparation and characterization of this composite can be considered as a hot issue for research. The study was carried out in several steps including: (i) preparation of Al/Al2O3 metal-based nanocompos...

Journal: :پرستاری قلب و عروق 0
سیده مریم شفیعی دارابی seyede-maryam shafiee-darabi حمیدرضا خانکه hamidreza khankeh مسعود فلاحی خشکناب masoud fallahi-khoshknab پوریارضا سلطانی pourya-reza soltani

aim. this study was conducted to examine the effect of acupressure on severity of pain and fatigue in patients with chronic heart failure. background. patients with chronic heart failure experience high levels of pain and fatigue. acupressure is a simple, inexpensive and non-invasive method which may reduce the pain and fatigue in patients with chronic heart failure. method. in this single blin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید